Megger Testing of Busses, MCCs, and Distribution...

8981 dl's @ 6635 KB/s

doc
Megger Testing of Busses, MCCs, and Distribution...

Page 11 of 15. Subject: Megger Testing of Busses, MCCs, and Distribution Panels. Revision Number and Date: R 0 1/17/2011. Procedure No.: LUM-FFA-MNT-0016

http://gwenholladay.weebly.com/uploads/5/0/6/9/5069966/lum-ffa-mnt-0016__megger_testing_of_busses_mccs_and_distribution_panels__draft.docx

Date added: May 2, 2013 - Views: 47

doc
Megger Testing of Transformers Effective TBD -...

LUM-FFA-MNT-0020 Megger Testing of Transformers R0Page 19 of 20. Page ... Do not take megger readings while the ... Report discrepancies or unsatisfactory results to ...

http://gwenholladay.weebly.com/uploads/5/0/6/9/5069966/lum-ffa-mnt-0020__megger_testing_of_transformers__draft.docx

Date added: July 12, 2013 - Views: 71

doc
Test Reports Template - HHS.gov

Changes to this Test Report will be coordinated with and approved by the undersigned or their ... Test Reports Template Subject: Author: HHS EPLC Team Keywords:

http://www.hhs.gov/ocio/eplc/EPLC%20Archive%20Documents/46-Test%20Reports/eplc_test_reports_template.doc

Date added: September 1, 2011 - Views: 1162

doc
26 08 30 (16972) - Electrical Starting and Testing...

Note data on test report form..2 Megger test all insulators to ground..3 Megger test bussing phase to ground and phase to phase..4 DC hipot main bus, ...

http://www.infrastructure.alberta.ca/Content/docType486/Production/26_08_30B.doc

Date added: May 10, 2013 - Views: 71

doc
SECTION 16123 - School District of Palm Beach...

Megger report shall at a minimum include the following for the Commissioning Agent. Test date. Manufacture and model number of test equipment.

http://www.palmbeachschools.org/buildingdepartment/documents/260513ElectricalWireandCable.docx

Date added: January 9, 2014 - Views: 8

doc
assets.tequipment.net

Megger’s MIT420 Insulation Resistance and Continuity Tester has been the instrument of choice of Lou Iaconelli. ... Transfer this data to the customer report.

http://assets.tequipment.net/assets/1/26/Documents/Megger/MIT430_EN/mit430_en_doc_5.doc

Date added: September 22, 2015 - Views: 6

doc
MSFC Problem Reporting and Corrective Action...

MSFC Problem Reporting and Corrective ... Contractor Report Number E-009 JSC# -- KSC# -- Problem Title CONNECTOR PINS FAILED MEGGER EICN# -- ELEMENT ET ...

http://foia.msfc.nasa.gov/docs/praca/A08086.doc

Date added: May 3, 2013 - Views: 16

doc
Medium Voltage Power System Maintenance - Alberta

Record data on test report form..2 Megger test insulators to ground..3 Megger test bussing phase to ground, ... Medium Voltage Power System Maintenance ...

http://www.infrastructure.alberta.ca/Content/docType486/Production/26_13_90_PMS.doc

Date added: October 21, 2011 - Views: 75

doc
piyushpanchal2007.mynetworksolutions.com

-Cable megger report (primary prior to pulling) if not mechanical loop - Cable megger report (secondary after pulling) if not mechanical loop

http://piyushpanchal2007.mynetworksolutions.com/images/Inst._Insp._and_Qua._Con..doc

Date added: November 1, 2011 - Views: 41

doc
INTERNATIONAL MARITIME BUREAU - ubsho.com

(Megger test report to be included) NONE This is to declare that the undersigned has examined and filled all the items of this report before signed it. Based ...

http://www.ubsho.com/download/PSR-SURVEY%20REPORT/MA-REP-IN.doc

Date added: May 26, 2013 - Views: 7

doc
SECTION 16117 - FRDF TESTS - FAACO - Federal...

SECTION 16117 - FRDF TESTS. PART 1 ... These tests shall be completed using a 500V megger. ... The results shall be submitted to the COTR in a “separate” report ...

http://faaco.faa.gov/attachments/0700346_specs_9.doc

Date added: October 9, 2012 - Views: 71

doc
Electrical Systems Prefunctional Checklists and...

The report shall contain infrared photos of trouble spots ... MD Anderson Cancer Center electrical systems prefunctional checklists and start-ups 26 08 13 ...

http://www2.mdanderson.org/depts/cpm/standards/specs/div26/26%2008%2013.doc

Date added: November 23, 2011 - Views: 168

doc
TEST SPECIFICATION TEMPLATE

RTMx Report (RTMx) or Use Cases ... TEST SPECIFICATION TEMPLATE Author: USPTO Last modified by: Elaine Greene Created Date: 2/12/2009 2:01:00 PM Company: Galaxy ...

http://www.uspto.gov/about/vendor_info/current_acquisitions/sdi_ng/test_specifications_procedures.doc

Date added: September 24, 2011 - Views: 231

doc
Radio Technicians Survey slr/gmdss - ww2.eagle.org

Associated REPORT NO. DATE RADIO TECHNICIANS SURVEY. ... For NIS ships, transmitting results to be tested with MEGGER: MEGOHM (>50 MOHM dry, >5 humid) 7.

http://ww2.eagle.org/content/dam/eagle/forms/GMDSS-TECH.doc

Date added: November 25, 2014 - Views: 2

doc
www.lowellma.gov

Report sheets for Megger testing. DELIVERY, STORAGE, AND HANDLING. Deliver wire and cable properly packaged in factory fabricated type containers, or wound on NEMA ...

http://www.lowellma.gov/Purchasing/Lists/Solicitations/Attachments/151/16120%20Wire%20and%20Cables.DOC

Date added: February 8, 2015 - Views: 5

doc
Commissioning Sequence Progress Check Sheet

Report Submitted and Approved (cable megger; Grounding) _____ _____ O & M Manual (Final) Submitted _____ _____ Training Scheduled and Completed ...

http://www.umaec.umich.edu/wp-content/uploads/2013/10/Electrical-Power-Sys.doc

Date added: August 26, 2014 - Views: 3

doc
MSFC PRACA : 2003-02-12 07:54

CHROMALOX HEATER FAILED MEGGER TEST EICN# -- ELEMENT ET Contractor ... System ASSESSMENT ADDENDUM REPORT MSFC Report# A03584 IFA# -- Contractor RPT# E ...

http://foia.msfc.nasa.gov/docs/praca/A03584.doc

Date added: June 4, 2013 - Views: 17

doc
Meeting Agenda - Southern Illinois University...

Meeting Agenda. First Contingency ... Design Report. Requirements. Assignments. Poster. Requirements. Appendixes. Megger Test. High Potential. Elsco Instruction ...

http://www.engr.siu.edu/ugrad1/me495a/OUTGRESP/F08-72-Meeting_Agenda_3-26-09.doc

Date added: August 28, 2013 - Views: 1

doc
Section 26 05 13, Medium-Voltage Cables

SECTION 26 05 13. MEDIUM-VOLTAGE CABLES. ... The report shall provide conclusions and recommendations for corrective action. G. Online Partial Discharge Test: ...

http://www.cfm.va.gov/TIL/spec/260513.doc

Date added: November 3, 2011 - Views: 75

doc
faaco.faa.gov

Use a portable ground testing megger in accordance with manufacturer's instructions to test each ground or group of grounds.

http://faaco.faa.gov/attachments/16302N.doc

Date added: October 3, 2011 - Views: 61

doc
PART 1 GENERAL - GE Industrial

Inspect and report concealed damage to carrier within ... Megger and record readings for phase to phase, phase to ground. Individual lengths should be at least ...

http://apps.geindustrial.com/publibrary/checkout/2004%20CSI%20Master%20Format|26%2025%2000.20|generic

Date added: February 11, 2014 - Views: 43

doc
METEOR phase IV procedure - Department of...

phase iv procedures. 0000-00-ar-g general notes and comments. preamble: these instructions are intended to provide core maintenance procedures for vessels in phase iv ...

https://voa.marad.dot.gov/docs/Library/ship_manager/docs/Group%2015/METP4ROS.DOC

Date added: November 4, 2015 - Views: 4

doc
Outline of Final Report - ntl.bts.gov

FINAL REPORT. January 31, 2005. ... an ITS implantation plan is defined as a document that outlines a series of system operations and ... With a MEGGER meter, ...

http://ntl.bts.gov/lib/25000/25000/25039/ITS_Operational_Support-Final_UTRC.doc

Date added: September 9, 2012 - Views: 132

doc
www.courts.ca.gov

Provide a megger insulation test report of all field coils and armature windings; the megger reading to be a minimum of 500,000 ohms. Commutator: ...

http://www.courts.ca.gov/documents/OCCM-2012-01-CC-ATTACHMENT-2.docx

Date added: September 7, 2012 - Views: 19

doc
CONECTIV POWER DELIVERY - Maryland Public Service...

ELECTRIC SUBSTATION. TRANSMISSION . AND. DISTRIBUTION. OPERATIONS & MAINTENANCE PLAN. Date: December 30, 2002. TABLE OF CONTENTS. Title Page 1. Table of Contents

http://webapp.psc.state.md.us/intranet/maillog/content.cfm?filepath=C:%5CCasenum%5CAdmin%20Filings%5C60000-109999%5C86505%5CCPD%20maintenance%20program%20to%20MPSC.doc

Date added: February 18, 2014 - Views: 25

doc
9 - grouper.ieee.org

Diego M. Robalino Megger William J. Solano ABB Susmitha Tarlapally ABB Alexsandr Levin ... Each Technical Council Committee may nominate one report from each ...

http://grouper.ieee.org/groups/transformers/meetings/S2014-Savannah/Minutes/S14-AwardsReport.doc

Date added: September 4, 2014 - Views: 5

doc
Section 16910

An engineering appraisal report shall be provided at end of testing prior to acceptance and full energysation of equipment. 1.7 QUALITY ASSURANCE (QUALIFICATIONS)

http://www.kyaarch.com/SFO_Data_Center/Coordination/BICEComments2_6.29.12/FWA_Electrical/26%2008%2013.doc

Date added: June 11, 2015 - Views: 2

doc
TURN OVER PACKAGE GUIDE - Colarelli Construction

A. Megger armature windings and report results . ... Turn Over Package Guide. Title: TURN OVER PACKAGE GUIDE Author: Angela Last modified by: Angela Created Date:

http://colarelliconstruction.com/documents/turn_over_package_guide.doc

Date added: August 7, 2013 - Views: 130

doc
ETE-01-01: FORM 1 – RAIL BREAK REPORT

Installation Inspection and Testing Report. 17. ... Apparatus Inspection – Megger Test / Bell Test / Function Test (circle appropriate task) Project: ...

http://extranet.artc.com.au/docs/eng/signal/forms/construction/ESC2104F-03.doc

Date added: January 5, 2013 - Views: 5

doc
DRY-TYPE TRANSFORMERS (1000 VOLT AND LESS)

The transformers shall be designed, ... Type Test each model design and submit report. ... Power frequency withstand voltage test. Insulation resistance (Megger) test.

http://www.sea.siemens.com/us/internet-dms/internet/consultingengineerscomm/general/Docs/26%2022%2013%2063%2000%20LV%20TRANSFORMERS%20NEMA%20Premium%20Efficiency%20K-RATED.doc

Date added: December 23, 2012 - Views: 35

doc
REGULAR MEETING – MOTLEY CITY COUNCIL

Employee Leave Report. ... Barros talked about a “megger” that will send a high voltage through the windings of the motor and it will tell if there is a short ...

http://www.cityofmotley.com/vertical/sites/%7B72EE7511-647E-4EE1-B547-F867A5FD103C%7D/uploads/%7B027A81C2-376D-4AAB-9E60-169E8724319F%7D.DOC

Date added: October 12, 2014 - Views: 1

doc
HQ 112378 - U.S. Customs and Border Protection

November 30, 1992. VES-13-18-CO:R:IT:C 112378 MLR. CATEGORY: Carriers. Deputy Assistant Regional Commissioner. Classification and Value Division. ATTN: Regional ...

http://rulings.cbp.gov/hq/1992/112378.doc

Date added: December 17, 2013 - Views: 1

doc
METHOD STATEMENT FOR - xa.yimg.com

METHOD STATEMENT FOR . ... (with the quantity mentioned in report) would be made to the KM material section. ... Megger / Clamp A.V.O.

http://xa.yimg.com/kq/groups/26854886/475930343/name/Method+Statement+overhead+power+line.doc

Date added: June 1, 2012 - Views: 116

doc
Question - Seattle

SCL Megger Test Form. Test Specification and MEGGER Test Form. CAD Drawing Requirements . ... The report shall include a description of the tests to be performed, ...

http://www.seattle.gov/purchasing/docs/bids/ITBSCL1189A101813.doc

Date added: October 31, 2013 - Views: 97

doc
7 - transformerscommittee.org

Diego M. Robalino IEEE/PES/SA status confirmed Megger Wally Binder. WG C57 ... A copy of the Membership Application is attached as an Annex to this Secretary’s Report.

http://www.transformerscommittee.org/meetings/S2014-Savannah/Minutes/S14-SecretaryReport.doc

Date added: May 24, 2014 - Views: 3

doc
ELECTRONICS 102 DC - Heartland Community College

Inductors Reactance include report and excel graph # 21-1. Inductive circuits include report . 4-15-13. ... Megger Lab if time allows. Relay Lab using the ...

http://www.technology.heartland.edu/faculty/chrism/ac%20dc/Spring%202013%20ELTC%20103%20schedule.docx

Date added: May 4, 2013 - Views: 32

doc
PART 1 – GENERAL - Hammond Power Solutions

Type Test each model design and submit report. ... (Megger) test. Positive sequence impedance. No load and full load losses in watts. Sound level in decibels.

http://www.hammondpowersolutions.com/files/HPS_Spec_1.2kV_Eff_Distribution_Transformer.doc

Date added: November 10, 2013 - Views: 35

doc
HQ 112478 - U.S. Customs and Border Protection

March 30, 1993. VES-13-18 CO:R:IT:C 112478 GFM. CATEGORY: Carriers. Chief, Technical Branch. Commercial Operations. Pacific Region. 1 World Trade Center. Long Beach ...

http://rulings.cbp.gov/hq/1993/112478.doc

Date added: August 12, 2013 - Views: 1

doc
www.psc.utah.gov

WHEREAS, Seller expects that the Facility will deliver to PacifiCorp '''''''''''''''''''' MWh of Net Output per calendar year, as adjusted due to annual degradation ...

http://www.psc.utah.gov/utilities/electric/14docs/1403546/253742Redacted%20Replacement%20PPA%20with%20Pavant%20Solar%204-24-2014.docx

Date added: May 13, 2014 - Views: 29

doc
www.ehs.berkeley.edu

Commission and submit the report to CFM prior testing. Horn/Strobes - Functional Test. ... Megger Test Feeders. Torque Feeder/Breaker Lugs. T-Bar. Service. Temporary ...

http://www.ehs.berkeley.edu/sites/default/files/lines-of-services/fire-prevention/ConstructiInspection%20Checklist.IS20150615.docx

Date added: September 1, 2015 - Views: 1

doc
Condition Survey Report Form - iopai.com

Are cargo hoses regularly -- megger tested? ... Rev 2 10/2013 IOPAI Condition Survey Report Form Page 5 of 25. Title: Condition Survey Report Form Author:

http://www.iopai.com/userfiles/files/Indian%20Ocean%20Club%20-%20Condition%20Survey%20Report%20(Others).doc

Date added: January 30, 2015 - Views: 42

doc
ETE-01-01: FORM 1 – RAIL BREAK REPORT

Title: ETE-01-01: FORM 1 – RAIL BREAK REPORT Author: katrina bowden Last modified by: jspa1 Created Date: 11/26/2007 6:12:00 AM Company: Protech Australasia

https://extranet.artc.com.au/docs/eng/signal/forms/maintenance/SMP23F-05.doc

Date added: January 12, 2016 - Views: 1

doc
SECTION 16210-1 - static.schneider-electric.us

C. Inspect and report concealed damage to carrier within their required time period. D. Store in a clean, dry space. ... B. Measure, using a Megger, ...

http://static.schneider-electric.us/docs/csi-specifications/33%2071%2073.10.EU.doc

Date added: October 28, 2013 - Views: 6

doc
ELECTRONICS 102 DC - Heartland Community College

Inductors Reactance include report and excel graph # 21-1. Inductive circuits include report . 4-11-11. ... Megger Lab if time allows. Relay Lab using the ...

http://www.technology.heartland.edu/faculty/chrism/ac%20dc/Spring%202011%20ELTC%20103%20schedule.docx

Date added: August 19, 2013 - Views: 24

doc
SECTION 16326000 - ABB Group

Megger. Ratio. Resistance. Phase relation. Load Loss, Impedance and Regulation. ... A certified test report containing minimum information per IEEE C57.12.91 .

https://library.e.abb.com/public/f9bb4235396918d8c1257b130057ecd6/1LUB000004-SPE_DryOW-VPI_ANSI.doc

Date added: June 22, 2015 - Views: 6

doc
Agenda - General Session - Transformers Committee

Secretary’s Report – Susan McNelly. Membership Review. ... User Diego M. Robalino Megger Wally Binder. WG C57.125 (2.5yrs) Joe Watson. PTSC (2.5yrs) ...

http://www.transformerscommittee.org/meetings/F2014-WashingtonDC/Minutes/F14-SecretaryReport.doc

Date added: October 27, 2014 - Views: 1

doc
PART 1 – GENERAL - Hammond Power Solutions

Type Test each model design and submit report. ... (Megger) test. Positive sequence impedance. Heat run test for K-factor rating compliance per UL & CSA.

http://www.hammondpowersolutions.com/files/sps08rev6.doc

Date added: September 5, 2013 - Views: 18

doc
DIRECTIVE 16-7 - State University Construction...

Megger testing may be done. Use ... Existing underground conduits and manholes shall be surveyed prior to design manual phase and a report submitted to SUCF. The ...

http://www.sucf.suny.edu/pdf/dir/16-7.doc

Date added: January 29, 2012 - Views: 18

doc
Gasoline & diesel fuel bid 99 -...

Report should include a summary of annual maintenance activities, ... Using a megger, test the compressor and oil pump motor. Record values. Phase to phase.

http://vendornet.state.wi.us/vendornet/wais/docs/10809_0.DOC

Date added: November 10, 2011 - Views: 84